4. Gently re-direct the two red wires exiting the right hand side
of the digital humidistat top console so that they exit the top
console from the left hand side, same side as the two black
wires (fig. 10)
5. Taking care not to pinch any wires and ensuring that the
humidistat sensor wire exits the digital humidistat top console
from the “T” slot on the back of the console, replace the
humidistat console onto the top of the humidistat cabinet, and
secure it in place using the two screws removed in step 4.
6. Remove the 2 - #6 screws which hold the humidifier side in
place (a short handled screw driver will give you easier access
to the screws) (fig 11.)
7. Lift the humidifier side out of the right hand position, turn the
part and position it on the other side of the humidifier. (fig. 12)
8. Use the 2 screw removed in step 3 to secure the humidifier
side in the left hand side.
STEP #2: MOUNTING THE HUMIDIFIER ON THE DUCT
If you have not already done so remove the humidifier cover –
secured in place with a 10-24 plastic thumb screw at the bottom
of the cover. Tilt the cover away from the body slightly (approx.
1/2") and then lift up the cover to free the hooks at the top of the
unit. Remove all loose components packaged inside and any
packaging. With a firm pull, disconnect the water tube from the
water nozzle and remove the evaporator pad assembly by sliding
it toward the top of the humidifier, then lifting it out. (fig 8.) – The
humidifier comes humidifier mounting template – Ensure the
cabinet is installed level for proper operation.
Before mounting the Model 6000 humidifier cabinet onto the
duct furnace duct, the humidistat sensor, located at the end of
the wire exiting from the “T” shaped slot on the back of the
humidifier, must be secured in place. This is done be gently
tucking the wire into the “T” slot, hooking the larger tab on the
sensor housing into the top of the “T” slot and firmly bringing
down the sensor housing until the smaller tabs on the sensor
housing snap into the sides of the “T” slot (see fig. 13)
CAUTION: When cutting or drilling into ducting take care not to
damage any air-conditioning coils or other furnace apparatus
CAUTION: Wear safety glasses and work gloves when installing
this unit. Sharp metal edges can cause severe injury.
1. Use adhesive tape to affix the template onto the duct in the
selected location. Use the level line to the template and a
level to ensure the cabinet will be level.
2. Drill the 4 marked cabinet mounting holes on the template
using a 1/8" drill bit (not supplied)
3. Using a 3/8" drill bit (not supplied) drill a hole inside the
rectangle marked “HUMIDIFIER CUT OUT”.
4. Using the 3/8" hole drilled in step 3 as a starting point cut out
the Humidifier Cut Out area marked on the template using tin
snips (not supplied). Cut on the outside of the line to ensure
a proper fit.
5. Mount the humidifier cabinet on the duct with 4 of the screws
from the installation package. Level the humidifier before
tightening the screws. (fig. 14)
6
Model 6000 Flow Through Humidifier
Figure 10