1. MAIN ON/OFF POWER BUTTON FOR THE HUMIDIFIER. –
Use this button only when turning ON or OFF the humidifier.
2. REDUCE RELATIVE HUMIDITY SET POINT BUTTON. – Use
this button only when reducing the relative humidity set point.
3. INCREASE RELATIVE HUMIDITY SET POINT BUTTON. – Use
this button only when increasing the relative humidity set point.
4. DIGITAL DISPLAY. – Displays (fig 32) a) User Set Point. b) Set
Point Number Indication. c) Humidifier Operating Indication.
d) Actual relative humidity being sensed. e) Incremental bar
indicating relative humidity status as it relates to the set point.
5. MAIN POWER GREEN LED. – Indicates that the main power
to the humidifier is ON.
When power is first turned on to the humidifier the digital
humidistat will display the default set point, which is 35%. You
may change this setting by using the Increase or Decrease button
on the control. If for some reason the power is lost to the
humidifier (power outage or unit becomes unplugged) there is a
delay (30 sec to 1 min) before the control loses it’s set point,
however if power is lost for any length of time the control will
revert to the default settings. If you notice that the control is
consistently resetting to the set point this is an indication that, a)
You have not wired (or plugged in the transformer) the
transformer to a CONSTANT 120 volt supply (one which cannot
be shut off via a switch) or b) The power connections (Two Black
Wires) to the humidifier are loose.
What is displayed will depend on what the set point is, what the
relative humidity being sensed is, and if the set point is being
changed.
DIGITAL DISPLAY WHEN CHANGING THE HUMIDITY LEVEL (FIG 33)
When you start to change the set point (raising or lowering) the
display will change, showing two numbers and a pointing finger
(the water droplets may be displayed as well depending on what
the relative humidity status was before you started changing the
set point). The number displayed beside the pointing finger is the
set point and is the number you are changing – The larger
number on the left of the display is the actual relative humidity
being sensed.
DIGITAL DISPLAY WHEN HUMIDIFIER HAS REACHED THE SET
POINT (FIG 34)
When the relative humidity being sensed raises above the set
point the humidifier does not need to run and the control display
will be similar to above – It will show two numbers and a pointing
finger. The number displayed beside the pointing finger is the set
point – The larger number on the left of the display is the actual
relative humidity being sensed.
DIGITAL DISPLAY WHEN HUMIDIFIER IS HUMIDIFYING. (FIG 35)
When the humidifier is adding moisture to air the display will
change – In the top right of the display will be a number, this is
the set point. - In the mid lower section of the display will be
water droplets, this is indicating that the humidifier is adding
moisture. - The remaining portion of the display will be taken up
by a slanted incremental bar, This bar represents the percentage
of the set point achieved.
SLANTED INCREMENTAL BAR.
When humidifying the control will display the set point and a bar
representing the percentage of set point achieved – each bar
represent approximately 10% of the set point. Below are a few
examples of humidifying displays showing a set point, an
incremental bar, and what relative humidity they represent.
1. Set point 40% - 50% of bars showing - relative humidity 20%
2. Set point 45% - 80% of bars showing – relative humidity 36%
3. Set point 50% - 50% of bars showing – relative humidity 25%
CONTROLLING THE HUMIDITY LEVEL
AND HUMIDIFIER OPERATION
HUMIDIFIER START UP.
When you first plug in the 24 Volt transformer and turn on your
humidifier you may hear a click. This is the power getting to the
control’s relay – As well if you adjust the digital humidistat UP or
DOWN and past the sensed humidity level you may hear the
control’s relay clicking. This is normal as the humidistat is just an
ON/OFF switch, every time the digital humidistat is turned
DOWN the power is cut to the HUMIDISENSE control.
When starting up the humidifier for operation:
1. Make sure the transformer is plugged in and the water supply
is turned on.
2. Make sure main power to the humidifier is turned ON.
3. Turn the humidistat up high, so it is calling for humidity.
4. Turn your furnace thermostat UP so the furnace cycles ON.
5. Once the HUMIDISENSE control senses heat the humidifier will
turn ON. You will know because the green “HUMIDISENSE”
LED (fig. 23) on the front of the humidifier will turn ON.
6. After a few moments you should hear water trickling through
the drain.
7. After your furnace has complete the heating cycle and shut off
11