IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
electric shock and injury to person, including the following:
SAVE THESE INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnect-
ing means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturer’s guideline and
safety standards such as those published by the National Fire Protection
Association (NFPA) and the American Society for Heating, Refrigeration,
and Air Conditioning Engineers (ASHRAE), and the local code authori-
ties.
c) When cutting or drilling into wall or ceiling, do not damage electrical wir-
ing and other hidden utilities.
CAUTION: TO REDUCE THE RISK OF FIRE AND TO PROPERLY
EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE - DO NOT VENT EX-
HAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS,
CRAWL SPACES, OR GARAGES.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT
USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
WARNING: TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when flambé-
ing food (ie. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan filter.
d) Use proper pan size. Always use cookware appropriate for the size
of the surface element.
WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal
tray, then turn off burner. BE CAREFUL TO PREVENT BURNS. If the
flames do not go out immediately, EVACUATE AND CALL THE FIRE
DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
d) Use an extinguisher ONLY if:
I. You know you have a Class ABC extinguisher, and you
already know how to operate it.
II. The fire is small and contained in the area where it started.
III. The fire department is being called.
IV. You can fight the fire with your back to an exit.
WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCTWORK.
www.airkinglimited.com
A111597011 Rev. G 4-12 1 of 16
Range Hood
Professional Series
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - OPERATING MANUAL

IMPORTANT INSTRUCTIONS -OPERATING MANUALREAD AND SAVE THESE INSTRUCTIONSREAD CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE

Page 2

INSTRUCTIONS D’INSTALLATIONAVERTISSEMENT : VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION.SECTION

Page 3

AVERTISSEMENT : EN RAISON DE LA HAUTEUR DE LA HOTTE, ASSUREZ-VOUS QUE LA BANDE DE BOIS EST FIXEE A TOUS LES MONTANTS MURAUX DISPONIBLES (UN MINIMUM DE

Page 4

2. L’épaisseur des bandes doit être la même que le retrait des armoires et elles doivent être d’une largeur d’environ 2 po.3. Installez les bandes e

Page 5

Figure 18Alimentation provenant de la maisonTerre (Vert ou nu)Vivant (noir)Neutre (blanc)www.airkinglimited.comA111597011 Rev. G 4-12 13 of 16SECTION

Page 6 - CUSTOMER SERVICE:

www.airkinglimited.comA111597011 Rev. G 4-12 14 of 16Installateur : Date d’installation : Endroit de l’achat : Numéro de modèle : Guide de dépan

Page 7 - REPLACEMENT PARTS DIAGRAM

www.airkinglimited.comA111597011 Rev. G 4-12 15 of 16TABLEAU DES PIÈCES DE RECHANGE # de pièce # Qté. Description de remplacement

Page 8

www.airkinglimited.comA111597011 Rev. G 4-12 16 of 16REMARQUE

Page 9 - MODE D’EMPLOI

INSTALLATION INSTRUCTIONSCAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION.SECTION 1Preparing the Range Hood1. U

Page 10 - SECTION 3

CAUTION: SUPPORT THE HOOD UNTIL IT IS FULLY INSTALLED ONTO THE WOOD MOUNTING STRIP.3. Rest the cavity in the back side of the hood on the wood strip

Page 11 - SECTION 6

2. The thickness of the strips should be the same as the recess of the cabinet and they should be approximately 2” wide.3. Install the strips using

Page 12 - SECTION 7

www.airkinglimited.comA111597011 Rev. G 4-12 5 of 16Figure 18Supply from houseGround (Green or Bare)Hot (Black)Neutral (White)SECTION 8Installing the

Page 13 - SECTION 12

Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1. Hood does not operate when the switch is on. 1a. A fuse may be blown or

Page 14 - SERVICE À LA CLIENTÈLE :

www.airkinglimited.comA111597011 Rev. G 4-12 7 of 16 # Qty. Description Replacement Part # 1 1 Wire Box 5S1136064 2 1 Wire Bo

Page 15

www.airkinglimited.comA111597011 Rev. G 4-12 8 of 16NOTES

Page 16 - REMARQUE

www.airkinglimited.comA111597011 Rev. G 4-12 9 of 16Hotte de CuisineSéries ProfessionnellesINSTRUCTIONS IMPORTANTES – MODE D’EMPLOICONSERVER CES INSTR

Comments to this Manuals

No comments