READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions should always be followed to reduce
the risk of fire, electric shock and injury to person, including the following:
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, AND INJURY
TO PERSONS, PROFESSIONAL SERIES RANGEHOODS MUST BE INSTALLED WITH
PROFESSIONAL SERIES RANGEHOOD BLOWERS THAT ARE MARKED (ON THEIR
CARTONS) TO INDICATE THE SUITABILITY WITH THIS MODEL. OTHER BLOWERS CANNOT
BE SUBSTITUTED.
1. Read all instructions before installing or using range hood.
2. Use this unit only in the manner intended by the manufacturer. If you have questions,
contact the manufacturer.
3. Before servicing or cleaning the unit, switch power off at service panel and lock
the service disconnecting means to prevent power from being switched on
accidentally. When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.
4. This unit must be grounded.
5. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall
spray, construction dust, etc. off power unit.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY
TO PERSON, OBSERVE THE FOLLOWING:
a.) Installation work and electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards, including fire-related
construction.
b.) Sufficient air is needed for proper combustion and exhausting of gases through
the flue (chimney) of fuel burning equipment to prevent back drafting. Follow
the heating equipment manufacturer’s guideline and safety standards such as
those published by the National Fire Protection Association (NFPA) and the
American Society for Heating, Refrigeration, and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
c.) When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
d.) Ducted fans must always be vented to the outdoors.
CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST
HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
CAUTION: TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR,
BE SURE TO DUCT AIR OUTSIDE - DO NOT VENT EXHAUST AIR INTO SPACES WITHIN
WALLS OR CEILINGS OR INTO ATTICS, CRAWL SPACES, OR GARAGES.
Professional Series
Range Hood
SAVE THESE INSTRUCTIONS
CAUTION: TO REDUCE THE RISK OF FIRE AND ELECTRIC SHOCK, INSTALL
THIS RANGEHOOD ONLY WITH INTEGRAL BLOWERS MANUFACTURED BY AIR KING,
MODEL(S) B1125, B900, B600, B500, OR B300 ONLY.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT USE
THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
WARNING: TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers cause smoking
and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when flambéing food (ie.
Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed to accumulate
on fan filter.
d) Use proper pan size. Always use cookware appropriate for the size of the
surface element.
WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn
off burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out
immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels - a violent steam
explosion will result.
d) Use an extinguisher ONLY if:
I. You know you have a Class ABC extinguisher, and you already know how
to operate it.
II. The fire is small and contained in the area where it started.
III. The fire department is being called.
IV. You can fight the fire with your back to an exit.
WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - OPERATING MANUAL

www.airkinglimited.com00000000 Rev. B 3-08 1 of 20READ AND SAVE THESE INSTRUCTIONSREAD CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MA

Page 2 - SECTION 2

www.airkinglimited.com00000000 Rev. B 3-0810 of 20AVERTISSEMENT : EN RAISON DE LA HAUTEUR DE LA HOTTE,ASSUREZ-VOUS QUE LA BANDE DE BOIS EST FIXEE A TO

Page 3

00000000 Rev. B 3-08www.airkinglimited.com 11 of 202. L’épaisseur des bandes doit être la même que le retrait des armoires et elles doiventêtre d’une

Page 4 - Wood Strip

www.airkinglimited.com 12 of 2000000000 Rev. B 3-08SECTION 7CâblageAVERTISSEMENT : TOUTES LES CONNEXIONS DOIVENT ÊTRE FAITESEN CONFORMITÉ AVEC LES COD

Page 5

Guide de dépannageTrouble Cause possible Solution suggérée1. La hotte ne fonctionne pas lorsque 1a. Un fusible peut être grillé ou un disjoncteur peut

Page 6 - Troubleshooting Guide

www.airkinglimited.com 14 of 2000000000 Rev. B 3-08

Page 7 - 00000000 Rev. B 3-08 7 of 20

www.airkinglimited.com00000000 Rev. B 3-0815 of 20Serie ProfesionalADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIO, CHOQUEELÉCTRICO Y LESIONES A PERSO

Page 8

www.airkinglimited.com00000000 Rev. B 3-0816 of 20INSTRUCCIONES DE INSTALACIÓNPRECAUCIÓN: ASEGÚRESE QUE EL SUMINISTRO ELÉCTRICO ESTÉAPAGADO EN UN PANE

Page 9

www.airkinglimited.com00000000 Rev. B 3-0817 of 20PRECAUCIÓN: DEBIDO AL PESO DE LA CAMPANA, ASEGÚRESE QUE ELLISTÓN DE MADERA ESTÉ SUJETADO A TODOS LOS

Page 10 - SECTION 6

00000000 Rev. B 3-08www.airkinglimited.com 18 of 20NOTA: Cuando el acabado de la tubería sea similar al que se muestra en la figura 15(pasando a travé

Page 11 - Languette en bois

Figura 21Canaleta para grasaCanalwww.airkinglimited.com 19 of 2000000000 Rev. B 3-08Figura 19Conector decablesTornillo3. Instale los filtros deflector

Page 12 - Figure 23

NOTE: When determining the height of the canopy from the cooking surface, be sure totake into consideration items such as back splashes with shelves a

Page 13 - GARANTIE LIMITÉE

GARANTÍA LIMITADATodos los productos fabricados por Air King Limited están garantizados por un año desde la fecha de compra contra defectos de fabrica

Page 14 - 00000000 Rev. B 3-08

www.airkinglimited.com00000000 Rev. B 3-08CAUTION: DUE TO THE WEIGHT OF THE HOOD, ENSURE THE WOOD STRIPIS FASTENED TO ALL AVAILABLE WALL STUDS (A MINI

Page 15

NOTE: When the duct termination is similar to that shown in figure 15 (passing throughthe wall to which the hood is mounted) the installation requires

Page 16 - SECCIÓN 3

3. Install the baffle filters along with any spacer bars that are required by insertingthe top of the filter into the top channel of the hood, then sl

Page 17 - SECCIÓN 6

LIMITED WARRANTYAll products manufactured by Air King Limited are warranted for one year from the date of purchase against defects in workmanship and/

Page 18 - Listón de Madera

www.airkinglimited.com00000000 Rev. B 3-08 7 of 20

Page 19 - Figura 20

www.airkinglimited.com00000000 Rev. B 3-088 of 20LIRE ET CONSERVER CES INSTRUCTIONSLIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER O

Page 20 - Guía de Solución de Problemas

www.airkinglimited.com00000000 Rev. B 3-08INSTRUCTIONS D’INSTALLATIONAVERTISSEMENT : VOUS ASSURER QUE L’ALIMENTATION ESTCOUPÉE AU PANNEAU DE SERVICE A