Air King AV1363 Instruction Manual

Browse online or download Instruction Manual for Cooker hoods Air King AV1363. Air King AV1363 Instructions User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions should always be followed to
reduce the risk of fire, electric shock and injury to person, including the following:
SAVE THESE INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service panel
and lock the service disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting means cannot
be locked, securely fasten a prominent warning device, such as a tag, to
the service panel.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturer’s guideline and
safety standards such as those published by the National Fire Protection
Association (NFPA) and the American Society for Heating, Refrigeration,
and Air Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO
EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
CAUTION: TO REDUCE THE RISK OF FIRE AND TO PROPERLY
EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE - DO NOT VENT EXHAUST
AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS, CRAWL
SPACES, OR GARAGES.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using range hood.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO
NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
WARNING: TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when flambéing
food (ie. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan filter.
d) Use proper pan size. Always use cookware appropriate for the size
of the surface element.
WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray,
then turn off burner. BE CAREFUL TO PREVENT BURNS. If the flames do
not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
d) Use an extinguisher ONLY if:
I. You know you have a Class ABC extinguisher, and you already
know how to operate it.
II. The fire is small and contained in the area where it started.
III. The fire department is being called.
IV. You can fight the fire with your back to an exit.
WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCTWORK.
www.airkinglimited.com
6728002 Rev. F 1-11 1 of 12
Range Hood
AV Series
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - OPERATING MANUAL

IMPORTANT INSTRUCTIONS -OPERATING MANUALREAD AND SAVE THESE INSTRUCTIONSREAD CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE

Page 2

www.airkinglimited.com6728002 Rev. F 1-11 10 of 12Guide de dépannage Trouble Cause possible Solution suggérée 1. La hotte ne fonctionne pas lor

Page 3 - SECTION 7

www.airkinglimited.com6728002 Rev. F 1-11 11 of 12GARANTIE LIMITÉECE QUE COUVRE CETTE GARANTIE : Ce produit est garanti contre tout vice de fabricatio

Page 4

www.airkinglimited.com6728002 Rev. F 1-11 12 of 12DIAGRAMME DES PIÈCES DE REMPLACEMENT # de pièce # Qte. Description de remplacement

Page 5 - CUSTOMER SERVICE:

INSTALLATION INSTRUCTIONSCAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION.SECTION 1Preparing the Range Hood1. U

Page 6 - REPLACEMENT PARTS DIAGRAM

www.airkinglimited.com6728002 Rev. F 1-11 3 of 124. Install an approved wire connector to the electrical knockout of the hood and guide the electrica

Page 7 - MANUAL DE OPERACIÓN

SECTION 9OperationControlsYour Range Hood is equipped with two rocker style switches with one controlling the lighting and the other controlling the e

Page 8 - SECTION 4

www.airkinglimited.com6728002 Rev. F 1-11 5 of 12LIMITED WARRANTYWHAT THIS WARRANTY COVERS: This product is warranted against defects in workmanship a

Page 9

www.airkinglimited.com6728002 Rev. F 1-11 6 of 12 # Qty. Description Replacement Part # 1 1 Filter RF35 5S4199011 2 1 Push Nut 5S4

Page 10 - SECTION 10

www.airkinglimited.com6728002 Rev. F 1-11 7 of 12INSTRUCCIONES IMPORTANTES – MANUAL DE OPERACIÓNLIRE ET CONSERVER CES INSTRUCTIONSLIRE SOIGNEUSEMENT A

Page 11 - SERVICE À LA CLIENTÈLE :

www.airkinglimited.com6728002 Rev. F 1-11 8 of 12INSTRUCTIONS D’INSTALLATIONMISE EN GARDE : ASSUREZ-VOUS QUE L’ALIMENTATION ÉLECTRIQUE EST COUPÉE À PA

Page 12 - 6728002 Rev. F 1-11 12 of 12

www.airkinglimited.com6728002 Rev. F 1-11 9 of 12Figure 7Neutre(blanc) de la lumièreChaud (noir)Mise à la terre (vert ou nu)Neutre (blanc) de la moteu

Comments to this Manuals

No comments