Air King Advantage Professional Series Troubleshooting Guide Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
www.airkinglimited.com
A111597016 Rev. F 4-12 5 of 16
SECTION 8
Installing the Blower
1.
Refer to the instructions inc
luded with the blower for installation.
SECTION 9
Installing the Optional Soffits
1.
Refer to the instructions inc
luded with the specific soffit(s) you have chosen for installation.
SECTION 10
Finishing the Installation
1.
Install the proper lighting for your specific unit:
Halogen Lamps:
Use PAR16 medium base 45W maximum lamps (available separately).
Install by inserting lamp into socket and turning clockwise until lamp is firmly seated. DO NOT
over tighten.
Heat Lamps:
Use type R40, medium base IR 250W max lamps only (available
separately). Install by inserting lamp into socket and turning clockwise until lamp is
firmly seated. DO NOT over tighten.
2. Install the grease filters by inserting the bottom of the filter into the bottom channel of the
hood compressing the spring, then slide the top of the filter into the top channel of the
hood (Figure 18).
SECTION 11
Operation
Controls
Your Range Hood is equipped with two rotary switches with one controlling the lighting and
the other controlling the exhaust fan blower. The light switch has three positions, High, Low,
and OFF. The fan switch has four positions, Off, High, Medium, and Low (Figure 19).
NOTE: On installation where a One (1) speed blower is utilized, all blower control speeds
operate at the same speed. On installation where a Two (2) speed blower is utilized, the
Medium and High speeds operate at the same speed.
Heat Lamp Controls: For models equipped with heat lamps, two On/Off rocker switch are
located on the front underside of the hood for independent control of the heat lamps (Figure 19).
Thermostat
Your hood is equipped with a thermostat that will automatically turn the hood on when the
temperature exceeds a set point. Once the temperature drops, the thermostat will turn the
hood off.
CAUTION: THE HOOD SHOULD ALWAYS BE TURNED ON OR OFF USING THE
CONTROL PANEL ANYTIME THE COOKING SURFACE IS BEING USED. DO NOT RELY ON THE
THERMOSTAT AS THE SOLE MEANS OF TURNING THE HOOD ON OR OFF!
Figure 18
Top
Channel
Bottom
Channel
SECTION 12
Maintenance
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE
SERVICING THE UNIT.
Grease Filters
Included with your range hood are grease filters along with a grease trough that should be
washed at least once a month. The grease filters are dishwasher safe and should be washed
in a mild soap or detergent. Reverse the instruction in SECTION 10 Finishing the Installation,
to remove the grease filters and trough. If the grease filters become damaged, replace with Air
King Models:
AP1030: Model GF1030 Grease Filters
AP1036:
Model GF1036 Grease Filters
AP1830:
Model GF1830 Grease Filters
AP1836:
Model GF1836 Grease Filters
CAUTION: ALLOW BULB TO COOL BEFORE REPLACING.
Changing the Lamps
Unscrew the lamp by turning in a counter-clockwise direction and remove from the socket.
Replace with a PAR16 medium base 45W maximum Halogen lamp. Installation is the reverse
of removal.
Cleaning
CAUTION: DO NOT USE GASOLINE, BENZINE, THINNER, HARSH CLEANSERS, ETC.,
AS THEY MAY DAMAGE THE RANGE HOOD.
1.
Clean your range hood with a mild detergent,
such as dishwashing liquid, and dry with a
soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Completely dry
before restoring power. NEVER IMMERSE ELECTRICAL PARTS IN WATER.
2.
The blo
wer assembly can be vacuumed when build up (dirt, lint, etc.) accumulates over
time. The blower is permanently lubricated and does not require oiling.
Light Switch
Blower Switch
Figure 19
Heat Lamp Switch
Page view 4
1 2 3 4 5 6 7 8

Comments to this Manuals

No comments