Air King ESB130SH Instruction Manual

Browse online or download Instruction Manual for Unknown Air King ESB130SH. Air King ESB130SH Instructions / Assembly User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
electric shock and injury to person, including the following:
SAVE THESE INSTRUCTIONS
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If
you have questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
f) This unit must be grounded.
g) To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
h) NEVER place a switch where it can be reached from a tub or
shower.
i) Suitable for use with electronic speed control device.
j) Do not install into ceilings thermally insulated to a value greater
than R40.
CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT
USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND
VAPORS.
WARNING: DO NOT USE IN KITCHENS.
k) Read all instructions before installing or using exhaust fan.
www.airkinglimited.com
6728020 New 3-12 1 of 12
Exhaust Fan
Models: ES80SH, ES130SH,
ES80DH, ES130DH
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - OPERATING MANUAL

IMPORTANT INSTRUCTIONS -OPERATING MANUALREAD AND SAVE THESE INSTRUCTIONSREAD CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE

Page 2 - SECTION 1

3. Installer la bride de montage du plafond pour couvrir tout espacement qui existe entre le châssis et le plafond fini. Aligner les fentes dans la br

Page 3 - SECTION 6

www.airkinglimited.com6728020 New 3-12 11 of 12Guide de dépannage Trouble Cause Possible Solution Suggérée 1. Le ventilateur ne fonctionne pas lo

Page 4

www.airkinglimited.com6728020 New 3-12 12 of 12DIAGRAMME DES PIÈCES DE REMPLACEMENT # Qty. Description Replacement Part # 1 1 Cabinet du venti

Page 5 - CUSTOMER SERVICE:

INSTALLATION INSTRUCTIONSCAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION.SECTION 1Preparing the Exhaust Fan1.

Page 6 - REPLACEMENT PARTS DIAGRAM

1b. Internal Wire Compartment: Using a 7/16" socket, remove the two hex nuts holding the blower assembly in place. Lift up on the assembly and s

Page 7 - MODE D’EMPLOI

4. Install the grill by squeezing the two ends of the springs together and installing them up into the slots on the fan’s housing. Push the grill up

Page 8

www.airkinglimited.com6728020 New 3-12 5 of 12Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1. Fan does not operate when th

Page 9

www.airkinglimited.com6728020 New 3-12 6 of 12REPLACEMENT PARTS DIAGRAM # Qty. Description Replacement Part # 1 1 Fan Housing 5S1239009 2

Page 10 - SECTION 8

INSTRUCTIONS IMPORTANTES – MODE D’EMPLOILIRE ET CONSERVER CES INSTRUCTIONSLIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPA

Page 11 - SERVICE À LA CLIENTÈLE :

INSTRUCTIONS D’INSTALLATIONAVERTISSEMENT : VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION.SECTION

Page 12 - UNITÉS À DEUX VITESSES

1b. Compartiment de Câblage Intérieur: Enlever les trois vis retenant en place l’assemblage de la soufflante et soulever pour sortir l’assemblage hors

Comments to this Manuals

No comments