IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
SAVE THESE INSTRUCTIONS
www.airkinglimited.com
6728087 Rev. D 1-16 1 of 12
Exhaust Fan with Light
AKLC70 Series
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
injury to person, including the following:
WARNING:
TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING: TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer’s guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
CAUTION: FOR GENERAL VENTILATING USE ONLY.
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH
ANY SOLID-STATE SPEED CONTROL DEVICE.
WARNING: DO NOT INSTALL OVER A TUB OR MOUNT IN A
SHOWER STALL ENCLOSURE.
WARNING: DO NOT USE IN KITCHENS.
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - OPERATING MANUAL

IMPORTANT INSTRUCTIONS -OPERATING MANUALSAVE THESE INSTRUCTIONSwww.airkinglimited.com6728087 Rev. D 1-16 1 of 12Exhaust Fan with LightAKLC70 SeriesREA

Page 2

www.airkinglimited.com6728087 Rev. D 1-16 10 of 124. Connecter le cordon des socles de lampe dans le réceptacle approprié.5. Aligner les fentes dans

Page 3 - SECTION 6

www.airkinglimited.com6728087 Rev. D 1-16 11 of 12GARANTIE LIMITÉEQUE COUVRE CETTE GARANTIE : Ce produit est garanti contre tout vice de fabrication

Page 4

www.airkinglimited.com6728087 Rev. D 1-16 12 of 12DIAGRAMME DES PIÈCES DE REMPLACEMENT123456789101112# Qté. Description# de pièce de remplacement1 4 T

Page 5 - CUSTOMER SERVICE:

INSTALLATION INSTRUCTIONSCAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION.SECTION 1Preparing the Exhaust Fan1.

Page 6 - REPLACEMENT PARTS DIAGRAM

1b. Internal Wire Compartment: Remove the screw holding the blower assembly in place. Lift up on the assembly and tilt it at a 45° angle to remove fr

Page 7 - MODE D’EMPLOI

www.airkinglimited.com6728087 Rev. D 1-16 4 of 124. Plug cord from lamp holders into the appropriate receptacle.5. Line up slots in the grill with l

Page 8 - SECTION 5

www.airkinglimited.com6728087 Rev. D 1-16 5 of 12Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1. Fan does not operate when

Page 9

www.airkinglimited.com6728087 Rev. D 1-16 6 of 12REPLACEMENT PARTS DIAGRAM123456789101112# Qty. Description Replacement Part #1 4 Mounting Rails 5S129

Page 10 - SECTION 7

INSTRUCTIONS IMPORTANTES – MODE D’EMPLOICONSERVER CES INSTRUCTIONSwww.airkinglimited.com6728087 Rev. D 1-16 7 of 12Exhaust Fan with LightSérie AKLC70L

Page 11 - SERVICE À LA CLIENTÈLE :

INSTRUCTIONS D’INSTALLATIONATTENTION : VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION.SECTION 1Pré

Page 12 - 6728087 Rev. D 1-16 12 of 12