Air King ASLC120 Specifications Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
www.airkinglimited.com
12
Specifications subject to change without notice
ENERGY STAR
®
qualified
Solution for ASHRAE 62.2 continuous whole house ventilation
Can be used to comply with California Title 24 as well as CALGreen
(humidity sensing models meet the CALGreen requirements for use in bathrooms)
8 capacity settings on low speed allow the fan to be set to the required exhaust
rate for continuous ventilation. Low speed set points include:
30, 40, 50, 60, 70, 90, 100 and 120 CFM
High speed rapidly clears the air of moisture, odors or other contaminants.
High speed set points include: 80, 110, 130 and Boost
Boost speed provides extra ventilation for installation with higher static pressure
and ensures airflow requirements are met when used to comply with ASHRAE 62.2
6" Round duct connector with gasketed damper protects against back drafts and
seals the duct better than any other damper on the market today
Listed for installation over a tub or shower on a GFCI circuit
Hanger bar installation
Available in contractor packs
(see your local representative for details)
Variable Speed Exhaust Fans
Variable Speed Exhaust Fans
MODEL
CFM
@ .1 SP
CFM
@ .25 SP
SONES
@ .1 SP WATTS LIGHTING LISTING
DUCT
SIZE HOUSING SIZE
ECO-EXHAUST FANS
ESVD 130 93/112
2
<0.3 30.0 N/A ETL 6" 127/8"W x 12¾"D x 97/8"H
ECO-EXHAUST FANS with MOTION SENSOR
Integrated motion sensor detects occupancy of the room and turns the fan to high speed and keeps it running for the preset time
after the room is vacated before automatically turning the fan back to low speed. Timer can be set from 30 seconds to 80 minutes.
ESVDG 130 93/112
2
<0.3 30.0 N/A ETL 6" 127/8"W x 12¾"D x 97/8"H
ECO-EXHAUST FANS with MOTION SENSOR and HUMIDITY SENSOR
Integrated motion sensor detects occupancy of the room and turns the fan to high speed and keeps it running for the preset time
after the room is vacated before automatically turning the fan back to low speed. Timer can be set from 30 seconds to 80 minutes.
Integrated humidistat senses the humidity level of the room and turns the fan to high speed until the humidity level is below the
preset level. Can be set up to 80% RH. The fan can also be activated through a wall control switch.
ESVDGH 130 93/112
2
<0.3 30.0 N/A ETL 6" 127/8"W x 12¾"D x 97/8"H
ECO-EXHAUST FANS with HUMIDITY SENSOR
Integrated humidistat senses the humidity level of the room and turns the fan to high speed until the humidity level is below the
preset level. Can be set up to 80% RH. The fan can also be activated through a wall control switch.
ESVDH 130 93/112
2
<0.3 30.0 N/A ETL 6" 127/8"W x 12¾"D x 97/8"H
ESVG and ESVGH
2
Boost speed provides 112 CFM, 0.6 sones, 0.30 amps @ .25 Static Pressure