3 When there is access to the top of the unit, connect the ducting to the duct collar and
secure in place using tape to seal all joints (Figure 5).
4. When there is no access to the top of the hood, carefully pull down the metal duct
through the custom hood base hole. Slide this duct over the duct collar. Make sure the
adapter/damper assembly enters the ducting. Seal the connection with duct tape.
SECTION 5
Wiring
CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE IN
ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF
YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE
SERVICES OF A QUALIFIED ELECTRICIAN.
1. Remove the two wire compartment cover screws
to gain access into the wire compartment (Figure
6). Connect the white wire from the range hood to
the white wire from the supply, and the black wire
from the range hood to the black wire of the supply.
Connect the ground wire from the home (green or
bare) to the ground wire (green) from the hood. Use
approved methods for all connections (Figure 7).
2. Replace the wire compartment cover and tighten
screws. Make sure all wiring is securely contained
within the wire compartment. If the quick connect
wire connector was removed from the receptacle,
replace. The connector will only fit one way into the
receptacle (Figure 6).
SECTION 6
Installing the Blower
1. Refer to the instructions included with the specific blower you have chosen for installation.
SECTION 7
Finishing the Installation
1. Install the proper lighting for your specific unit:
Halogen Lamps: Use PAR16 medium base 45W maximum Halogen lamps. Install
by inserting lamp into socket and turning clockwise until lamp is firmly seated. DO
NOT over tighten.
Wire Connector
Figure 6
Screws
Supply from house
Ground
(Green or Bare)
Neutral
(White)
Hot (Black)
Figure 7
Outlet Adapter
Hood
Screws
Flange
Figure 5
Ducting
2. If the included removable grease trough is not already installed within the hood, insert
into the rear inside channel of the hood. Make sure the taller side of the trough is facing
towards the back of the hood (Figure 8).
3. Install the baffle filters and any spacers included with the unit by inserting the top of the filter
into the top channel of the hood, then slide the bottom of the filter into the bottom channel.
The filters have a top and a bottom. The bottom of the filter will have small drain holes.
These holes must be facing down towards the grease trough to be effective (Figure 9).
SECTION 8
Operation
Controls
Your Liner is equipped with two rotary switches with one controlling the lighting and the other
controlling the exhaust fan blower. The light switch has three positions, High, Low, and Off.
The fan switch has four positions, Off, High, Medium, and Low (Figure 10).
Thermostat
Your Liner is equipped with a thermostat that will automatically turn the Liner on when the
temperature exceeds a set point. Once the temperature drops, the thermostat will turn the Liner off.
CAUTION: THE LINER SHOULD ALWAYS BE TURNED ON OR OFF USING THE
CONTROL PANEL ANYTIME THE COOKING SURFACE IS BEING USED. DO NOT RELY ON THE
THERMOSTAT AS THE SOLE MEANS OF TURNING THE LINER ON OR OFF!
SECTION 9
Maintenance
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE
SERVICING THE UNIT.
Grease Baffles
Included with your range hood are stainless steel grease baffles along with a grease trough
that should be washed at least once a month. The baffles and trough are dishwasher safe and
should be washed in a mild soap or detergent. Reverse the instruction in SECTION 8 Finishing
the Installation, to remove baffles and trough. If the grease baffles become damaged, replace
with the appropriate Air King Grease Baffles as described in the parts diagram.
Bottom
Channel
2
1
3
Figure 10
Light Switch
Blower Switch
Figure 8
Grease Trough
Channel
Figure 9
Top
Channel
Page view 2
1 2 3 4 5

Comments to this Manuals