READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
electric shock and injury to person, including the following:
WARNING: DO NOT CONNECT POWER SUPPLY UNTIL FAN
IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE
TO THE FAN IS LOCKED IN OFF POSITION.
WARNING: MODEL AIDB4Y DRYER BOOSTER FAN IS NOT
EXPLOSION PROOF. DO NOT USE IF A POTENTIALLY EXPLOSIVE
SITUATION MAY EXIST.
1. Read all instructions before installing or using fan.
2. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
3. Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
4. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-related construction.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
Models: AIDB4Y, AILT4
www.airkinglimited.com
AIDB4YEF New 3-07
Dryer Booster Fan
SAVE THESE INSTRUCTIONS
CAUTION: FOR GENERAL VENTILATING USE ONLY. DO
NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS
AND VAPORS.
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off
power unit.
9. This unit has rotating parts and safety precautions should be
exercised during installation, operation and maintenance.
10. Guards must be installed when fan is within reach of personnel
or within seven (7) feet of working level or when deemed
advisable for safety.
11. DO NOT insert or allow fingers or foreign objects to enter the
motor.
12. DO NOT use with heated air in excess of 140°F (60°C).
IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
1 of 8
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - OPERATING MANUAL

READ AND SAVE THESE INSTRUCTIONSREAD CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECTYOURSELF AND

Page 2 - SECTION 3

INSTALLATION INSTRUCTIONSCAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICEPANEL BEFORE STARTING INSTALLATION.SECTION 1Preparing for Installation1. F

Page 3 - SECTION 4

www.airkinglimited.comAIDB4YEF New 3-07 3 of 82. Bring incoming electrical service through the romex connectorand the fan knockout. Be sure to place t

Page 4 - Troubleshooting Guide

Troubleshooting GuideTrouble Probable Cause Suggested Remedy1. Fan does not operate when dryer begins cycle. 1a. A fuse may be blown or a circuit trip

Page 5 - MANUEL D’OPÉRATION

LIRE ET CONSERVER CES INSTRUCTIONSLIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZVOUS-MÊME

Page 6

INSTALLATION INSTRUCTIONSAVERTISSEMENT: VOUS ASSURER QUE L’ALIMENTATIONEST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCERL’INSTALLATION.SECTION 1Prép

Page 7

www.airkinglimited.comAIDB4YEF New 3-07 7 of 82. Amener le service électrique au travers du connecteur romex et del’alvéole défonçable du ventilateur.

Page 8 - GARANTIE LIMITÉE

Guide de dépannageTrouble Cause Possible Solution Suggérée1. Le ventilateur ne fonctionnera pas lorsque 1a. Un fusible peut être grillé ou un disjonct